وارد شدن | ثبت نام
产品中心
صفحه اول > مرکز محصولات > Vacuum circuit Breaker > Indoor Vacuum circuit Breaker > Indoor HV Fixed VCB ZN63(VSG)-12

Indoor HV Fixed VCB ZN63(VSG)-12

    Indoor HV Fixed VCB ZN63(VSG)-12

    Indoor High Voltage Fixed Vacuum Circuit Breaker AP-VSG-24 VSG -24 series indoor side mounted high voltage vacuum circuit breaker is indoor high voltage switchgear is suitable for three-phase power systems with a rated voltage of 24kV and a rated frequency of 50 Hz as a function of protection and control of electrical appliances, due to the special advantages of vacuum circuit breakers especialy for places requiring frequent operation at rated current or multiple short-circuit currents VSG-24 series side mounted vacuum circuit breaker is fixedly installed and is mainly used for fixed switch...
  • اشتراک گذاری:
  • با ما تماس بگیرید استعلام آنلاین
  • ایمیل:ansel@apexe.cc

Indoor High Voltage Fixed Vacuum Circuit Breaker AP-VSG-24

VSG -24 series indoor side mounted high voltage vacuum circuit breaker is indoor high voltage Switchgear is suitable for three-phase power systems with a rated voltage of 24kV and a rated frequency of 50 Hz as a function of protection and control of electrical appliances, due to the special advantages of vacuum circuit breakers especialy for places requiring frequent operation at rated current or multiple short-circuit currents VSG-24 series side mounted vacuum circuit breaker is fixedly installed and is mainly used for fixed switchgearThe circuit breaker can be used alone or for ring network power supply, box type or various non-standard power supply systems.

 

APPLYING AMBIENT CONDITIONS

1.Ambient temperature: -30°C~+40°C.

2.Relative humidity: the average humidity of a day should be no more than95%.The average humidity of a month should be no more than 90%.

3.Earthquake intensity: not exceed 8 degrees.

4.Saturated vapor pressure: the average pressure of a day should be no more than 2.2kPa; the average pressure of a month should be no more than1.8Kpa.

5.The height above sea level: 1000 m (Except special requirements).

6.It should be installed in the places without fire, explosion, serious filth,and chemicalerosion and violent vibration.

 



No.ItemUnitData
1Rated voltageKV24
2Rated frequencyHZ50/60
3Rated insulation level1 min power frequency withstand voltageKV65
Lightning impulse withstand voltage125
4Rated currentA630
1250
5Rated short-circuit breaking currentKA20
25
31.5
6Rated short circuit closing current(peak)KA50
63
80
7Contact resistance per phasemm≤50
≤45
8Contact opening distancemm12±1
9Overtravelms3.5±0.5
10Contact closing bounce timems≤2
11Three phase opening and closing not synchronismms≤2
12Opening timems20-50
13Closing timems30-70
14Average opening timem/s1.1-1.6
15Average closing timem/s0.5-1.0




پیام آنلاین

لطفا یک آدرس ایمیل معتبر وارد کنید
کد تایید نمیتواند خالی باشد

محصولات مرتبط

هنوز هیچ نتیجه جستجویی وجود ندارد!

Contact Information

Indiana Office

995 Green Hill St. Greenfield, IN 46140

1-800-1234-567

mail@demolink.org

New York Office

995 Green Hill St. Greenfield, IN 46140

1-800-1234-567

mail@demolink.org

Search

این وب سایت از کوکی ها استفاده می کند تا اطمینان حاصل شود که بهترین تجربه را در وب سایت ما به دست می آورید.

قبول کنید رد کردن