وارد شدن | ثبت نام
产品中心
صفحه اول > مرکز محصولات > Switchgear > Gas Insulated Switchgear > SF6 Gas Insulated Switchgear Metal Enclosed High Voltage Medium Voltage Indoor Outdoor Compact Design IEC Certified Substation Electrical Distribution Cabinet

SF6 Gas Insulated Switchgear Metal Enclosed High Voltage Medium Voltage Indoor Outdoor Compact Design IEC Certified Substation Electrical Distribution Cabinet

    SF6 Gas Insulated Switchgear Metal Enclosed High Voltage Medium Voltage Indoor Outdoor Compact Design IEC Certified Substation Electrical Distribution Cabinet

    The SF6 Gas Insulated Switchgear is a compact, metal-enclosed solution for high and medium voltage applications. Suitable for indoor and outdoor substations, it ensures reliable electrical distribution. IEC certified, this switchgear cabinet provides safe, efficient, and durable performance for modern power systems, optimizing space without compromising safety or functionality.
  • اشتراک گذاری:
  • با ما تماس بگیرید استعلام آنلاین
  • ایمیل:ansel@apexe.cc

APR6-12/24/40.5 series of SF6 Gas Insulated Metal Enclosed Switchgear (c-GlS) is independently developed by our company with sulfur hexafluoride gas as the insulating medium and can be applied in primary or secondary power distribution at a same time. lt is a new-generation medium-voltage whole-set switchgear with vacuum arc extinguishing technology, APG solid sealed technology, gas insulation technology and interface insulation technology. The product has passed the type test verification and new product technology appraisal by China’s national authoritative testing institution, The product can be widely used in various important power distribution and substation systems of China’s national economy, such as power distribution and substation network, urban power supply network, large industrial and mining enterprises, petrochemical, metallurgy, urban rail transit and so on.


The product has a modular design and can be combined according to various design schemes. The product has a sealed pressure system and all high-voltage live parts of its main circuit are sealed in the stainless steel gas tank without influence from environments. It runs reliably, is compact with little space occupied and free from maintenance.

Main Technical Parameters


ItemUnitParameter
Rated voltagekV12 24 40.5
Rated frequencyHz50
Rated currentA630/1250/2500/3150/4000/630/1250/2500
Power frequency withstand voltage (phase-to-phase and phase-to-ground)kV42 65 95
Power frequency withstand voltage (insulation breaking)kV48 79 118
Lightning impulse withstand voltage (phase-to-phase and phase-to-ground)kV75 125 185
Lightning impulse withstand voltage (insulation breaking)kV85 145 215
Rated power frequency withstand voltage of auxiliary circuitkV2
Rated instantaneous withstand currentkA25/31.5/40
Rated short-circuit periods3
Rated peak withstand currentkA63/80/100 63/80/100 50/63/80
Rated short-circuit breaking current of circuit breakerkA25/31.5/40 25/31.5/40 25/31.5
Rated short-circuit closing current of circuit breaker (peak)kA63/80/100 63/80/100 50/63/80
Rated cable charge breaking currentA25
Rated operating sequence
O-0.3s-CO-3min-CO
Insulation gas
SF6
Mechanical lifeTime10000
Three-position switchTime5000
Rated charge pressure (abs, 20°C)Mpa0.14
Minimum charge pressure (abs, 20°C)Mpa0.12
Sealed enclosureGradeIP67
Switch shellGradeUP4X
Annual relative leak rate of dry air%/year≤0.1
Rated power voltage of auxiliary circuitVDC48/110/220 AC220

The SF6 gas insulated switchgear (GIS) is an advanced, compact, metal-enclosed electrical distribution solution designed for high and medium voltage applications. Its IEC certification ensures compliance with international safety and quality standards, making it a reliable choice for indoor and outdoor substations. With a compact design, durable construction, and efficient operation, this switchgear cabinet is suitable for modern Power Systems requiring space optimization, safety, and long-term reliability.


In this detailed guide, we cover applicationsafter-sales servicecommon issues, and daily maintenance of the SF6 GIS, providing a complete reference for operators, engineers, and procurement professionals.


Table of Contents

  1. Overview of SF6 Gas Insulated Switchgear

  2. Technical Specifications

  3. Applications and Suitable Environments

  4. Installation and Commissioning Guidelines

  5. Daily Maintenance and Inspection

  6. Common Issues and Troubleshooting

  7. After-Sales Service and Support

  8. Safety Considerations

  9. Advantages of Compact Metal-Enclosed Design

  10. Certifications and Compliance

  11. Conclusion


1. Overview of SF6 Gas Insulated Switchgear

The SF6 Gas Insulated Switchgear (GIS) is a key component in modern power systems, offering high reliability, compact design, and low maintenance. Its main features include:

  • SF6 Gas Insulation: Provides excellent dielectric properties and arc-quenching performance.

  • Metal-Enclosed Structure: Enhances mechanical protection and reduces risk of electrical accidents.

  • Compact Design: Ideal for installations with limited space, such as urban substations or indoor industrial facilities.

  • IEC Certification: Ensures compliance with international standards for safety and performance.

  • Indoor and Outdoor Use: Flexible for various environmental conditions.


2. Technical Specifications

The following table summarizes the key technical parameters of the SF6 GIS:

ParameterSpecification
Rated Voltage12kV – 72.5kV
Rated Current630A – 2500A
Short-Circuit Breaking Capacity20kA – 40kA
Insulation MediumSF6 Gas
Enclosure TypeMetal-Enclosed
Installation EnvironmentIndoor / Outdoor
Operating Frequency50Hz / 60Hz
Mechanical Endurance≥10,000 operations
Electrical Endurance≥2,000 operations
Ambient Temperature Range-40°C to +50°C
Protection ClassIP54 / IP65

This specification ensures reliable performance in demanding applications, from urban substations to industrial power distribution.


3. Applications and Suitable Environments

SF6 GIS is widely deployed in:

  • Substations: Medium and high-voltage substations for electricity transmission and distribution.

  • Industrial Facilities: Factories, manufacturing plants, and chemical plants requiring reliable power protection.

  • Urban Power Grids: Compact design is ideal for high-density areas with limited space.

  • Renewable Energy Plants: Wind, solar, and hydroelectric plants for efficient distribution.

  • Railway Electrification Systems: Provides stable and safe electrical supply for traction power.

Indoor vs Outdoor Use:

  • Indoor GIS: Installed in controlled environments, reduces exposure to weather, dust, and pollution.

  • Outdoor GIS: Designed with enhanced insulation and corrosion-resistant enclosures to withstand harsh weather conditions.


4. Installation and Commissioning Guidelines

4.1 Site Preparation

Before installation, ensure:

  • level and stable foundation with proper grounding.

  • Adequate clearance for operation, inspection, and maintenance.

  • Environmental conditions meet the specified temperature and humidity ranges.

4.2 Installation Procedure

  1. Positioning the Cabinet: Place the metal-enclosed switchgear according to layout drawings.

  2. Electrical Connections: Connect incoming and outgoing cables securely to the designated terminals.

  3. SF6 Gas Filling: Confirm the gas pressure is within the recommended range.

  4. Mechanical Alignment: Ensure all moving parts operate smoothly without obstruction.


  • صفحه قبلی: هیچ کدام باقی نمانده است
  • صفحه بعد: هیچ کدام باقی نمانده است

پیام آنلاین

لطفا یک آدرس ایمیل معتبر وارد کنید
کد تایید نمیتواند خالی باشد

محصولات مرتبط

هنوز هیچ نتیجه جستجویی وجود ندارد!

Contact Information

Indiana Office

995 Green Hill St. Greenfield, IN 46140

1-800-1234-567

mail@demolink.org

New York Office

995 Green Hill St. Greenfield, IN 46140

1-800-1234-567

mail@demolink.org

Search

این وب سایت از کوکی ها استفاده می کند تا اطمینان حاصل شود که بهترین تجربه را در وب سایت ما به دست می آورید.

قبول کنید رد کردن